DOI:
2006. . No. 1(31) – Mar 2006, pp. 16-17
Dynamic Compliance Estimation of the Turboset Foundations
Assessment methodology of dynamic impedance of concrete units is described. This technique is used to inspect foundations of power stations equipment. Vibration is generated by directional mechanical vibrator. Amplitudes of constrained vibration of foundations are measured in given frequency range. Coefficients are estimated and compared with the standardized measures in accordance with the inspection data dynamic compliance.