Issue << content << Quasi-Stabilization of Beam Transmission Angle within a Wide Temperature Range


DOI:

2007. . No. 4(38) - Dec 2007, pp. 43-45

Quasi-Stabilization of Beam Transmission Angle within a Wide Temperature Range

A. K. Gurvich, L. I. Kuzmina, S. V. Nikolaev, A. K. Shevchenko

Different ways of beam transmission angle stabilization are discussed: manufacture of transducer prisms of materials, where the longitudinal wave velocity does not depend on the temperature within the range ± 500 °С; manufacture of transducers with the prism combined of two materials, where correlation between longitudinal wave velocities and the temperature are opposite in sign; application of set of transducers, where each of them, with a correspondent angle of prism, provides preset transmission angle in a certain temperature interval within a range ± 50 °С.Recommendations for realization of the two last ways for the rail and other metal products inspection are given.
 
 